Mitsubishi Electric 600M Series Error SYW0002: RIO1 communication error

CNC milling machine · taken from the manufacturer’s manual, pages cited

Error codeSYW0002

An emergency stop input signal was received from a remote I/O unit (RIO1). Or, the communication cable with the remote I/O unit (RIO1) is not connected properly. The manual's first action is: “Examine the causes of the remote I/O unit emergency stop, and remove them.”

Model
Mitsubishi Electric 600M Series
Display shows
RIO1 communication error (SYW0002)
Type
Error code
Source
Manual p. 496

What SYW0002 means

RIO1 communication error p. 496

Common causes

  • An emergency stop input signal was received from a remote I/O unit (RIO1). Or, the communication cable with the remote I/O unit (RIO1) is not connected properly. p. 496

What to do

  1. Examine the causes of the remote I/O unit emergency stop, and remove them. p. 496
  2. Check the cable connection. p. 496

Before you service the product, read the safety instructions in the manual p. 4.

If SYW0002 is still not resolved

  • contact service / dealer p. 5
    “Do not change the fixed cycle program without prior consent from the machine manufacturer.”
  • contact service / dealer p. 5
    “Do not turn OFF the NC a”

This page summarises what the manufacturer’s manual says about SYW0002; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.