G27 and M commands in same block means a G27 command cannot be used with any individual M command within the same program block. The manual's first action is: “An M individual command cannot be issued in a G27 command block and so the G27 command and M individual command must be placed in separate blocks.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- G27 and M commands in same block (PR0435)
- Type
- Error code
- Source
- Manual p. 486
What PR0435 means
G27 and M commands in same block p. 486
Common causes
- An M individual command was issued simultaneously in the G27 command block. p. 486
What to do
- An M individual command cannot be issued in a G27 command block and so the G27 command and M individual command must be placed in separate blocks. p. 486
Before you service the product, read the safety instructions in the manual p. 4.
If PR0435 is still not resolved
This page summarises what the manufacturer’s manual says about PR0435; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.