Mitsubishi Electric 600M Series Error PR0155: Fix cyc executed during compen

CNC milling machine · taken from the manufacturer’s manual, pages cited

Error codePR0155

A fixed cycle command was executed while in radius compensation mode, which is not allowed and requires cancellation of compensation first. The manual's first action is: “The radius compensation mode is established when a fixed cycle command is executed and so the radius compensation cancel command (G40) should be issued.”

Model
Mitsubishi Electric 600M Series
Display shows
Fix cyc executed during compen (PR0155)
Type
Error code
Source
Manual p. 481

What PR0155 means

Fix cyc executed during compen p. 481

Common causes

  • A fixed cycle command has been issued in the radius compensation mode. p. 481

What to do

  1. The radius compensation mode is established when a fixed cycle command is executed and so the radius compensation cancel command (G40) should be issued. p. 481

Before you service the product, read the safety instructions in the manual p. 4.

If PR0155 is still not resolved

  • contact service / dealer p. 5
    “Do not change the fixed cycle program without prior consent from the machine manufacturer.”
  • contact service / dealer p. 5
    “Do not turn OFF the NC a”

This page summarises what the manufacturer’s manual says about PR0155; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.