Mitsubishi Electric 600M Series Error PR0039: No EOB

CNC milling machine · taken from the manufacturer’s manual, pages cited

Alarm codePR0039

The program block lacks an EOB code when an EOR (%) code was used. The manual's first action is: “Use an EOB code at the end of the program block.”

Model
Mitsubishi Electric 600M Series
Display shows
No EOB (PR0039)
Type
Alarm code
Source
Manual p. 478

What PR0039 means

No EOB p. 478

Common causes

  • There was no EOB code at the end of the program block, and an EOR (%) code resulted. p. 478

What to do

  1. Use an EOB code at the end of the program block. p. 478

Before you service the product, read the safety instructions in the manual p. 4.

If PR0039 is still not resolved

  • contact service / dealer p. 5
    “Do not change the fixed cycle program without prior consent from the machine manufacturer.”
  • contact service / dealer p. 5
    “Do not turn OFF the NC a”

This page summarises what the manufacturer’s manual says about PR0039; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.