Error codePR0036
"EOR" has been read during tape and memory operation. M02 and M30 are not entered at the end of the program. M99 is not entered at the end of the subprogram. (Or, G23 or G68 is not entered at the end. The manual's first action is: “Reconsider the program.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- Program end error (PR0036)
- Type
- Error code
- Source
- Manual p. 477
What PR0036 means
Program end error p. 477
Common causes
- "EOR" has been read during tape and memory operation. M02 and M30 are not entered at the end of the program. M99 is not entered at the end of the subprogram. (Or, G23 or G68 is not entered at the end of the subprogram when it is compliant with an M2/M0 format.) p. 477
What to do
- Reconsider the program. p. 477
Before you service the product, read the safety instructions in the manual p. 4.
If PR0036 is still not resolved
This page summarises what the manufacturer’s manual says about PR0036; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.