Error codeOPW0169
Rotary axis workpiece position compensation exceeded the 3mm limit and is invalid. The manual's first action is: “Turn the rotary axis workpiece position compensation OFF.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- Rotate work compen excessive (OPW0169)
- Type
- Error code
- Source
- Manual p. 504
What OPW0169 means
Rotate work compen excessive p. 504
Common causes
- The rotary axis workpiece position compensation amount exceeded 3mm. p. 504
What to do
- Turn the rotary axis workpiece position compensation OFF. p. 504
- Set the deviation between the workpiece center position and table rotation center to 3mm or less. p. 504
- Check that the workpiece coordinate zero point is set at the workpiece center. p. 504
Before you service the product, read the safety instructions in the manual p. 4.
If OPW0169 is still not resolved
This page summarises what the manufacturer’s manual says about OPW0169; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.