MELSERVO MR-J2S- /L50132B Error 92: Open battery cable warning

Servo amplifier and motor · taken from the manufacturer’s manual, pages cited

Warning code92

Open battery cable warning due to open cable or voltage below 2.8V. The manual's first action is: “Repair cable or changed.”

Model
MELSERVO MR-J2S- /L50132B
Display shows
Open battery cable warning (92)
Type
Warning code
Source
Manual p. 108

What 92 means

Open battery cable warning p. 114

Common causes

  • 1. Battery cable is open. p. 114
  • 2. Battery voltage dropped to 2.8V or less. p. 114

What to do

  1. Repair cable or changed. p. 114
  2. Change battery. p. 114

Before you service the product, read the safety instructions in the manual p. 2.

If 92 is still not resolved

  • contact service / dealer p. 2
    “Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly.”
  • contact service / dealer p. 3
    “Any person who is involved in wiring and inspection should be fully competent to do the work.”

This page summarises what the manufacturer’s manual says about 92; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with MELSERVO. Found a mistake? Report an error.