MELSERVO MR-J2S- /L50132B Error 52: Error excessive

Servo amplifier and motor · taken from the manufacturer’s manual, pages cited

Fault code52

Error excessive due to too small acceleration/deceleration time constant or torque limit value or power supply voltage drop. The manual's first action is: “Increase the acceleration/deceleration time constant.”

Model
MELSERVO MR-J2S- /L50132B
Display shows
Error excessive (52)
Type
Fault code
Source
Manual p. 108

What 52 means

Error excessive p. 113

Common causes

  • Acceleration/deceleration time constant is too small. p. 113
  • Torque limit value is too small. p. 113
  • Motor cannot be started due to torque shortage caused by power supply voltage drop. p. 113
  • Position control gain (parameter No.13) value is small. p. 113
  • Servo motor shaft was rotated by external force. p. 113
  • Machine struck something. p. 113
  • Encoder faulty p. 113
  • Wrong connection of servo motor. Servo amplifier's output terminals U, V, W do not match servo motor's input terminals U, V, W. p. 113

What to do

  1. Increase the acceleration/deceleration time constant. p. 113
  2. Increase the torque limit value. p. 113
  3. Review the power supply capacity. Use servo motor which provides larger output. p. 113
  4. Increase set value and adjust to ensure proper operation. p. 113
  5. When torque is limited, increase the limit value. Reduce load. Use servo motor that provides larger output. p. 113
  6. Review operation pattern. Install limit switches. p. 113
  7. Change the servo motor. p. 113
  8. Connect correctly. p. 113

Before you service the product, read the safety instructions in the manual p. 2.

If 52 is still not resolved

  • contact service / dealer p. 2
    “Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly.”
  • contact service / dealer p. 3
    “Any person who is involved in wiring and inspection should be fully competent to do the work.”

This page summarises what the manufacturer’s manual says about 52; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with MELSERVO. Found a mistake? Report an error.