A measuring unit without a reference point is connected, or the reference point signal wire is broken. The manual's first action is: “Connect a measuring unit with a reference point. If this does not correct the problem, contact your vendor.”
- Model
- Magnescale LY72
- Display shows
- Error in reference point detection (r.Error)
- Type
- Error code
- Source
- Manual p. 66
What r.Error means
Error in reference point detection p. 66
Common causes
- This is displayed when a measuring unit without a reference point is connected or when the reference point signal wire in a measuring unit with a reference point is broken. p. 66
What to do
- Connect a measuring unit with a reference point. If this does not correct the problem, contact your vendor. p. 66
If r.Error is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Magnescale service.
This page summarises what the manufacturer’s manual says about r.Error; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Magnescale. Found a mistake? Report an error.