Magnescale LY72 Error Error: Measuring unit not connected

Magnescale LY72 · taken from the manufacturer’s manual, pages cited

Error codeError

The measuring unit is not connected to the device. The manual's first action is: “Turn off the power, connect the measuring unit, and then turn on the power again. The display value is reset to zero.”

Model
Magnescale LY72
Display shows
Measuring unit not connected (Error)
Type
Error code
Source
Manual p. 66

What Error means

Measuring unit not connected p. 66

Common causes

  • The measuring unit is not connected. p. 66

What to do

  1. Turn off the power, connect the measuring unit, and then turn on the power again. The display value is reset to zero. p. 66
  2. Check that the measuring unit signal connector is secured by screws. p. 66
  3. Check that the conduit cable is not damaged or disconnected. p. 66
  4. Check to see if the measuring unit has moved faster than the maximum response speed, or if there was a large vibration. p. 66
  5. Check for high noise levels. (Try replacing with a normal axis.) p. 66
  6. Disconnect the AC adaptor, and then reconnect after 1 to 2 minutes. p. 66
  7. Perform resetting operation. p. 66

If Error is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Magnescale service.

This page summarises what the manufacturer’s manual says about Error; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Magnescale. Found a mistake? Report an error.