Magnescale Manuals

ManualLib has 8 Magnescale manuals covering 1 model. The most documented models are LY72. Every file can be read online or downloaded as a PDF for free.

User Manual 7

Key facts

Manuals
8
Models
1
Languages
JA · EN
Last added
2026-10-03

Magnescale models by category

Other 1

Latest Magnescale manuals

Which document do I need?

User Manual

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in Magnescale manuals

What is the recommended maximum length for the RS‑232C cable?

A cable length of no more than 15 m should be used.

From: Magnescale LY72 User Manual

What voltage levels does the driver side output provide?

The driver side output voltage ranges from ±5 V to ±10 V.

From: Magnescale LY72 User Manual

How do I recalculate the maximum and minimum values?

Use function 1‑5 “重新辻算最大値和最小値 (重新乾始功能)” to recompute the max and min measurements.

From: Magnescale LY71 (CS) User Manual

How can I change the measurement resolution?

Select function 1‑3 “変更星示解析度” to set a new resolution such as 0.005.

From: Magnescale LY71 (CS) User Manual

What power source should be used for the MG10‑P1/P2?

The device operates on DC power; AC must never be connected.

From: Magnescale MG10-P1/MG10-P2 Instruction Manual

Can the MG10 units be used in explosive gas atmospheres?

No, the units are not explosion‑proof and must not be used where flammable gases are present.

From: Magnescale MG10-P1/MG10-P2 Instruction Manual