Invt Electric CHV100 Error OL2: Inverter overload

Invt Electric CHV100 inverter · taken from the manufacturer’s manual, pages cited

Fault codeOL2

Inverter overload means the inverter is drawing too much current, possibly due to heavy load, short acceleration/deceleration time, or insufficient inverter capacity. The manual's first action is: “1. Increase Acc/Dec time or select bigger capacity inverter.”

Model
Invt Electric CHV100
Display shows
Inverter overload (OL2)
Type
Fault code
Source
Manual p. 113

What OL2 means

Inverter overload p. 113

Common causes

  • 1. Load is too heavy or Acc/Dec time is too short. p. 113
  • 2. Improper V/F curve p. 113
  • 3. Capacity of inverter is too small. p. 113

What to do

  1. 1. Increase Acc/Dec time or select bigger capacity inverter. p. 113
  2. 2. Check and adjust V/F curve. p. 113
  3. 3. Select bigger capacity inverter. p. 113

If OL2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Invt Electric service.

This page summarises what the manufacturer’s manual says about OL2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Invt Electric. Found a mistake? Report an error.