Invt Electric CHV100 Error OL1: Motor overload

Invt Electric CHV100 inverter · taken from the manufacturer’s manual, pages cited

Fault codeOL1

Motor overload means the motor is drawing too much current, possibly due to heavy load at low speed, improper V/F curve, or incorrect overload threshold. The manual's first action is: “1. Select variable frequency motor.”

Model
Invt Electric CHV100
Display shows
Motor overload (OL1)
Type
Fault code
Source
Manual p. 113

What OL1 means

Motor overload p. 113

Common causes

  • 1. Motor drive heavy load at low speed for a long time. p. 113
  • 2. Improper V/F curve p. 113
  • 3. Improper motor's overload protection threshold (PB.03) p. 113
  • 4. Sudden change of load. p. 113

What to do

  1. 1. Select variable frequency motor. p. 113
  2. 2. Check and adjust V/F curve. p. 113
  3. 3. Check and adjust PB.03 p. 113
  4. 4. Check the load. p. 113

If OL1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Invt Electric service.

This page summarises what the manufacturer’s manual says about OL1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Invt Electric. Found a mistake? Report an error.