Inovance MD380M Error Err42: Excessive Speed Deviation Fault

Inovance MD380M Servo Driver · taken from the manufacturer’s manual, pages cited

Fault codeErr42

Excessive Speed Deviation Fault occurs when encoder parameters are incorrectly set, parameter identification is not performed, or speed deviation detection parameters are set unreasonably. The manual's first action is: “1. Set encoder parameters correctly”

Model
Inovance MD380M
Display shows
Excessive Speed Deviation Fault (Err42)
Type
Fault code
Source
Manual p. 218

What Err42 means

Excessive Speed Deviation Fault p. 218

Common causes

  • 1. Encoder parameters are set incorrectly p. 218
  • 2. Parameter identification has not been performed p. 218
  • 3. Speed deviation detection parameters F9-69 and F9-60 are set unreasonably p. 218

What to do

  1. 1. Set encoder parameters correctly p. 218
  2. 2. Perform motor parameter identification p. 218
  3. 3. Set detection parameters reasonably according to actual conditions p. 218

Before you service the product, read the safety instructions in the manual p. 8.

If Err42 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.

This page summarises what the manufacturer’s manual says about Err42; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.