Inovance MD380M Error Err41: Motor Switching Fault During Operation

Inovance MD380M Servo Driver · taken from the manufacturer’s manual, pages cited

Fault codeErr41

Motor Switching Fault During Operation happens when changing the current motor selection while the servo drive is running. The manual's first action is: “1. Perform motor switching after the servo drive has been stopped”

Model
Inovance MD380M
Display shows
Motor Switching Fault During Operation (Err41)
Type
Fault code
Source
Manual p. 218

What Err41 means

Motor Switching Fault During Operation p. 218

Common causes

  • 1. Changing the current motor selection via terminals while the servo drive is running p. 218

What to do

  1. 1. Perform motor switching after the servo drive has been stopped p. 218

Before you service the product, read the safety instructions in the manual p. 8.

If Err41 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.

This page summarises what the manufacturer’s manual says about Err41; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.