GSK GSK980TB3 Error 254: Preparation is not ready.

GSK GSK980TB3 · taken from the manufacturer’s manual, pages cited

Alarm code254

The system is not ready because the emergency stop is active. The manual's first action is: “Check whether the emergency stop button is pressed down, or change parameter NO.14 Bit3 to 1: Shield emergency stop.”

Model
GSK GSK980TB3
Display shows
Preparation is not ready. (254)
Type
Alarm code
Source
Manual p. 272

What 254 means

Preparation is not ready. p. 272

When MESP=1 , emergency stop is inactive. It is for debugging. When MESP=0 , emergency stop is active. It can be used normally. p. 231

Press the overtravel release button on the panel and move the axis reversely until it detaches the stroke switch, the alarm will be eliminated. p. 231

Common causes

  • CNC is in emergency stop state. p. 272

What to do

  1. Check whether the emergency stop button is pressed down, or change parameter NO.14 Bit3 to 1: Shield emergency stop. p. 272

If 254 is still not resolved

  • Check whether the emergency stop button is pressed down, or change parameter NO.14 Bit3 to 1: Shield emergency stop. p. 272
    “Check whether the emergency stop button is pressed down, or change parameter NO.14 Bit3 to 1: Shield emergency stop.”