GSK GS2000T Series Error Err-43: The check is wrong when EEPROM is read in the absolute encoder

AC servo drive unit · taken from the manufacturer’s manual, pages cited

Fault codeErr-43

The check is wrong when EEPROM is read in the absolute encoder means PA1 parameter setting is wrong, or when power on the data check is wrong after the drive unit reads EEPROM. The manual's first action is: “Call the correct motor's default value.”

Model
GSK GS2000T Series
Display shows
Err-43
Type
Fault code
Source
Manual p. 123

What Err-43 means

The check is wrong when EEPROM is read in the absolute encoder p. 123

Common causes

  • 1. PA1 parameter setting is wrong; p. 123
  • 2. When power on, the data check is wrong after the drive unit reads EEPROM. p. 123

What to do

  1. Call the correct motor's default value. p. 123
  2. Execute Ab-Set encoder write operation. p. 123

If Err-43 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.

This page summarises what the manufacturer’s manual says about Err-43; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GSK. Found a mistake? Report an error.