Reading EEPROM in the absolute encoder is wrong means PA1 parameter setting is wrong, or when power on the drive unit reading the encoder EEPROM is wrong, or the motor's encoder EEPROM is damaged. The manual's first action is: “Call the correct motor's default value.”
- Model
- GSK GS2000T Series
- Display shows
- Reading EEPROM in the absolute encoder is wrong (Err-42)
- Type
- Fault code
- Source
- Manual p. 123
What Err-42 means
Reading EEPROM in the absolute encoder is wrong p. 123
Common causes
- 1. PA1 parameter setting is wrong; p. 123
- 2. When power on, the drive unit reading the encoder EEPROM is wrong; p. 123
- 3. The motor's encoder EEPROM is damaged. p. 123
What to do
- Call the correct motor's default value. p. 123
- Check the encoder feedback CN2 wiring. p. 123
- Change the motor. p. 123
If Err-42 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.
This page summarises what the manufacturer’s manual says about Err-42; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GSK. Found a mistake? Report an error.