GSK GS2000T Series Error Err-38: Alarm occurs when the temperature is higher than 75°C.

AC servo drive unit · taken from the manufacturer’s manual, pages cited

Fault codeErr-38

Alarm occurs when the temperature is higher than 75°C means the motor overload running for a long time, or the environmental temperature is too high, or the servo drive unit is damaged. The manual's first action is: “Reduce the load.”

Model
GSK GS2000T Series
Display shows
Alarm occurs when the temperature is higher than 75°C. (Err-38)
Type
Fault code
Source
Manual p. 123

What Err-38 means

Alarm occurs when the temperature is higher than 75°C. p. 123

Common causes

  • 1. The motor overload running for a long time; p. 123
  • 2. The environmental temperature is too high; p. 123
  • 3. The servo drive unit is damaged. p. 123

What to do

  1. Reduce the load. p. 123
  2. Improve the ventilation condition. p. 123
  3. Change the drive unit. p. 123

If Err-38 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.

This page summarises what the manufacturer’s manual says about Err-38; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GSK. Found a mistake? Report an error.