FANUC B-65325CM/01 Error 2: Software disconnect (full closed-loop)

FANUC B-65325CM/01 · taken from the manufacturer’s manual, pages cited

Error code2

2 on the FANUC B-65325CM/01 is listed in the manual as: Software disconnect (full closed-loop). The manual's first action is: “Please verify that the separate detector correctly outputs position feedback pulses. When correct, a large gap between motor position and scale position can indicate that, at machine start-up, only the motor runs in reverse.”

Model
FANUC B-65325CM/01
Display shows
Software disconnect (full closed-loop) (2)
Type
Error code
Source
Manual p. 70

What 2 means

Software disconnect (full closed-loop) p. 70

Common causes

  • Occurs when the change in speed feedback pulses is large but the change in position feedback pulses is small. p. 70

What to do

  1. Please verify that the separate detector correctly outputs position feedback pulses. When correct, a large gap between motor position and scale position can indicate that, at machine start-up, only the motor runs in reverse. p. 70

Before you service the product, read the safety instructions in the manual p. 3.

If 2 is still not resolved

  • 请在故障的原因彻底清除之后再进行报警复位操作 p. 15
    “请在故障的原因彻底清除之后再进行报警复位操作”
  • 有关维护方面的疑问事项,请尽早与 FANUC 公司联络 p. 15
    “有关维护方面的疑问事项,请尽早与 FANUC 公司联络”

This page summarises what the manufacturer’s manual says about 2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FANUC. Found a mistake? Report an error.