2 on the FANUC B-65325CM/01 is listed in the manual as: Software disconnect (full closed-loop). The manual's first action is: “Please verify that the separate detector correctly outputs position feedback pulses. When correct, a large gap between motor position and scale position can indicate that, at machine start-up, only the motor runs in reverse.”
- Model
- FANUC B-65325CM/01
- Display shows
- Software disconnect (full closed-loop) (2)
- Type
- Error code
- Source
- Manual p. 70
What 2 means
Software disconnect (full closed-loop) p. 70
Common causes
- Occurs when the change in speed feedback pulses is large but the change in position feedback pulses is small. p. 70
What to do
- Please verify that the separate detector correctly outputs position feedback pulses. When correct, a large gap between motor position and scale position can indicate that, at machine start-up, only the motor runs in reverse. p. 70
Before you service the product, read the safety instructions in the manual p. 3.
If 2 is still not resolved
This page summarises what the manufacturer’s manual says about 2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FANUC. Found a mistake? Report an error.