01 on the FANUC B-65325CM/01 is listed in the manual as: No *ESP (including emergency stop, input, and contact signals) and MRDY (machine ready) were input, but SFR (forward rotation command), SRV (reverse rotation command), or ORCM (orientation command) were input.. The manual's first action is: “Confirm the sequence of *ESP and MRDY. For MRDY, pay attention to the parameter setting for using/not using the MRDY signal (NO.4001#0).”
- Model
- FANUC B-65325CM/01
- Display shows
- 01
- Type
- Error code
- Source
- Manual p. 104
What 01 means
No *ESP (including emergency stop, input, and contact signals) and MRDY (machine ready) were input, but SFR (forward rotation command), SRV (reverse rotation command), or ORCM (orientation command) were input. p. 104
Common causes
- No *ESP (including emergency stop, input, and contact signals) and MRDY (machine ready) were input, but SFR (forward rotation command), SRV (reverse rotation command), or ORCM (orientation command) were input. p. 104
What to do
- Confirm the sequence of *ESP and MRDY. For MRDY, pay attention to the parameter setting for using/not using the MRDY signal (NO.4001#0). p. 104
Before you service the product, read the safety instructions in the manual p. 3.
If 01 is still not resolved
This page summarises what the manufacturer’s manual says about 01; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FANUC. Found a mistake? Report an error.