Faldic MHT259a (RYS-L type) Error AL OF: Overflow, deviation excessive

AC Servo System · taken from the manufacturer’s manual, pages cited

Alarm codeAL OF

Overflow, deviation excessive means the difference between command and feedback position exceeded the set parameter limit. The manual's first action is: “The initial set value of basic para. 54 is 10000 (x 100) [pulse]. If the difference between the current command position and current feedback position exceeds 1000000 [pulse], an alarm is detected. Under normal operating conditions, the deviation amount increases in proportion to the motor speed. If an alarm is detected when rotating the motor by turning on the [RUN], the motor power wiring phases U, V, W may not be connected to the corresponding terminals (U, V, W) of the amplifier. The set value of basic para. 54 need not be decreased. The deviation amount can be reduced by setting the feed forward gain of basic para. 40 to near 1,000.”

Model
Faldic MHT259a (RYS-L type)
Display shows
Overflow, deviation excessive (AL OF)
Type
Alarm code
Source
Manual p. 326

What AL OF means

Overflow, deviation excessive p. 331

Common causes

  • Overflow, deviation excessive p. 331
  • Deviation amount (difference between the current command position and current feedback position) exceeded the set value of basic para. 54. p. 331

What to do

  1. The initial set value of basic para. 54 is 10000 (x 100) [pulse]. If the difference between the current command position and current feedback position exceeds 1000000 [pulse], an alarm is detected. Under normal operating conditions, the deviation amount increases in proportion to the motor speed. If an alarm is detected when rotating the motor by turning on the [RUN], the motor power wiring phases U, V, W may not be connected to the corresponding terminals (U, V, W) of the amplifier. The set value of basic para. 54 need not be decreased. The deviation amount can be reduced by setting the feed forward gain of basic para. 40 to near 1,000. p. 331

Before you service the product, read the safety instructions in the manual p. 3.

If AL OF is still not resolved

  • contact service / dealer p. 3
    “reference must be made to this manual and other related documents.”
  • contact service / dealer p. 4
    “Customers, who want to use the products introduced in this manual for special systems or devices such as for atomic-energy control, aerospace use, medical use, and traffic control, are requested to consult the Fuji.”

This page summarises what the manufacturer’s manual says about AL OF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Faldic. Found a mistake? Report an error.