Faldic MHT259a (RYS-L type) Error AL Fb: Fuse brown

AC Servo System · taken from the manufacturer’s manual, pages cited

Alarm codeAL Fb

Fuse brown indicates the main circuit fuse is blown due to excessive power, and cannot be replaced without contacting support. The manual's first action is: “The main circuit fuse is for preventing the secondary accident such as fire. The fuse cannot be replaced. Do not turn on power again, and contact us.”

Model
Faldic MHT259a (RYS-L type)
Display shows
Fuse brown (AL Fb)
Type
Alarm code
Source
Manual p. 326

What AL Fb means

Fuse brown p. 333

Common causes

  • Fuse brown p. 333
  • Voltage was generated at both ends of the fuse in the amplifier main circuit (≥2 [kW]). p. 333

What to do

  1. The main circuit fuse is for preventing the secondary accident such as fire. The fuse cannot be replaced. Do not turn on power again, and contact us. p. 333

Before you service the product, read the safety instructions in the manual p. 3.

If AL Fb is still not resolved

  • contact service / dealer p. 3
    “reference must be made to this manual and other related documents.”
  • contact service / dealer p. 4
    “Customers, who want to use the products introduced in this manual for special systems or devices such as for atomic-energy control, aerospace use, medical use, and traffic control, are requested to consult the Fuji.”

This page summarises what the manufacturer’s manual says about AL Fb; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Faldic. Found a mistake? Report an error.