Fagor Servo Drive System Error 304: Power supply (PS) power‑bus overvoltage.

Fagor Servo Drive System · taken from the manufacturer’s manual, pages cited

Error code304

Power supply (PS) power‑bus overvoltage means the power supply has detected an overvoltage on the power bus, possibly due to incorrect wiring or missing external ballast connection. The manual's first action is: “Turn off the power supply and verify that the wiring is correct. See errors 215 and 306.”

Model
Fagor Servo Drive System
Display shows
Power supply (PS) power‑bus overvoltage. (304)
Type
Error code
Source
Manual p. 547

What 304 means

Power supply (PS) power‑bus overvoltage. p. 547

Common causes

  • Power‑bus overvoltage detected on the power supply. The internal ballast may be disconnected (see power module). When using an external ballast, an error may occur due to missing connection. p. 547

What to do

  1. Turn off the power supply and verify that the wiring is correct. See errors 215 and 306. p. 547

Before you service the product, read the safety instructions in the manual p. 444.

If 304 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.

This page summarises what the manufacturer’s manual says about 304; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.