Connected motor differs from the motor configured in the fast memory means the drive’s RAM settings do not match the fast memory settings for the motor. The manual's first action is: “This error does not interrupt normal drive operation. To use the connected motor, store these parameters in the fast memory.”
- Model
- Fagor Servo Drive System
- Display shows
- 505
- Type
- Error code
- Source
- Manual p. 550
What 505 means
Connected motor differs from the motor configured in the fast memory. p. 550
Common causes
- The parameter settings in the drive's RAM are for the newly connected motor. However, the settings stored in the fast memory correspond to a different motor; in other words, MP1 in fast memory and RAM are not the same. p. 550
What to do
- This error does not interrupt normal drive operation. To use the connected motor, store these parameters in the fast memory. p. 550
Before you service the product, read the safety instructions in the manual p. 444.
If 505 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.
This page summarises what the manufacturer’s manual says about 505; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.