Fagor Servo Drive System Error 300: Power supply or integrated drive thermal sensor overheating.

Fagor Servo Drive System · taken from the manufacturer’s manual, pages cited

Error code300

Power supply or integrated drive thermal sensor overheating means the thermal sensor or drive has detected excessive heat, requiring reduced power demand. The manual's first action is: “Stop the system for a few minutes and reduce the power demand on the power module.”

Model
Fagor Servo Drive System
Display shows
Power supply or integrated drive thermal sensor overheating. (300)
Type
Error code
Source
Manual p. 547

What 300 means

Power supply or integrated drive thermal sensor overheating. p. 547

What to do

  1. Stop the system for a few minutes and reduce the power demand on the power module. p. 547

Before you service the product, read the safety instructions in the manual p. 444.

If 300 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.