Delta VFD110CT43F21A3 Error oSL: Over slip error

Delta VFD110CT43F21A3 · taken from the manufacturer’s manual, pages cited

Error codeoSL

Over slip error means the slip has exceeded the set point and duration limits. The manual's first action is: “Verify motor parameters are correct; if the load is excessive, reduce the load; confirm the settings of parameters 05-26 and 05-27”

Model
Delta VFD110CT43F21A3
Display shows
Over slip error (oSL)
Type
Error code
Source
Manual p. 301

What oSL means

Over slip error p. 301

Common causes

  • When slip exceeds the set point of parameter 05-26 and the duration exceeds the time set in parameter 05-27, an oSL occurs p. 301

What to do

  1. Verify motor parameters are correct; if the load is excessive, reduce the load; confirm the settings of parameters 05-26 and 05-27 p. 301

Before you service the product, read the safety instructions in the manual p. 291.

If oSL is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about oSL; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.