Delta VFD110CT43F21A3 Error cd2: lbs sensor err

Delta VFD110CT43F21A3 · taken from the manufacturer’s manual, pages cited

Error codecd2

The cd2 code indicates lbs sensor err, where V-phase current detection is abnormal. The manual's first action is: “Troubleshooting: Power cycle the unit; if the abnormality recurs, send to factory for repair.”

Model
Delta VFD110CT43F21A3
Display shows
lbs sensor err (cd2)
Type
Error code
Source
Manual p. 299

What cd2 means

lbs sensor err p. 299

Common causes

  • V‑phase current detection abnormal p. 299

What to do

  1. Troubleshooting: Power cycle the unit; if the abnormality recurs, send to factory for repair. p. 299

Before you service the product, read the safety instructions in the manual p. 291.

If cd2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about cd2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.