Delta VFD-VE 系列 Error oSL: When slip exceeds the limit set in parameter 05-26 and the duration exceeds the time set in parameter 05-27

Delta VFD-VE AC motor drive · taken from the manufacturer’s manual, pages cited

Error codeoSL

The oSL error code indicates slip has exceeded the limit set in parameter 05-26 for a duration exceeding the time set in parameter 05-27. The manual's first action is: “Check whether the motor parameters are correct; if the load is too heavy, reduce the load; confirm the settings of parameters 05-26 and 05-27.”

Model
Delta VFD-VE 系列
Display shows
oSL
Type
Error code
Source
Manual p. 239

What oSL means

When slip exceeds the limit set in parameter 05-26 and the duration exceeds the time set in parameter 05-27 p. 239

Common causes

  • When slip exceeds the limit set in parameter 05-26 and the duration exceeds the time set in parameter 05-27 p. 239

What to do

  1. Check whether the motor parameters are correct; if the load is too heavy, reduce the load; confirm the settings of parameters 05-26 and 05-27. p. 239

Before you service the product, read the safety instructions in the manual p. 72.

If oSL is still not resolved

  • Contact local agents for consultation. p. 4
    “若有任 何疑虑的地方请连络本公司各地的代理商洽询,我们的专业人员会乐于为您服务。”