Delta VFD-VE 系列 Error cP10: When the digital operator panel KPV-CE01 is the primary command source, connected to COM1 and communication times out beyond the time set in parameter 09-03, or connected to COM2 and times out beyond the time set in parameter 09-07

Delta VFD-VE AC motor drive · taken from the manufacturer’s manual, pages cited

Error codecP10

The cP10 error code indicates a communication timeout when the digital operator panel KPV-CE01 is the primary command source. The manual's first action is: “Check whether the communication line is abnormal; verify that the digital operator is functioning properly.”

Model
Delta VFD-VE 系列
Display shows
cP10
Type
Error code
Source
Manual p. 238

What cP10 means

When the digital operator panel KPV-CE01 is the primary command source, connected to COM1 and communication times out beyond the time set in parameter 09-03, or connected to COM2 and times out beyond the time set in parameter 09-07 p. 238

What to do

  1. Check whether the communication line is abnormal; verify that the digital operator is functioning properly. p. 238

Before you service the product, read the safety instructions in the manual p. 72.

If cP10 is still not resolved

  • Contact local agents for consultation. p. 4
    “若有任 何疑虑的地方请连络本公司各地的代理商洽询,我们的专业人员会乐于为您服务。”

This page summarises what the manufacturer’s manual says about cP10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.