Delta VFD-L Error oL2: Motor load too large

Delta VFD-L · taken from the manufacturer’s manual, pages cited

Error codeoL2

This code indicates motor load too large. The manual lists no action for this code.

Model
Delta VFD-L
Display shows
Motor load too large (oL2)
Type
Error code
Source
Manual p. 2

What oL2 means

Motor load too large p. 2

Common causes

  • Check whether the motor load is excessive p. 2
  • Check the over‑torque detection threshold settings (parameters 6‑03 to 6‑05) p. 2
  • Check that the wiring between the AC motor drive and motor is secure p. 2
  • Check whether the U/T1‑V/T2‑W/T3 output wiring is poorly insulated p. 2
  • Increase the acceleration time p. 2
  • Decrease the torque boost setting (parameter 7‑02) p. 2
  • Replace with a higher‑output‑capacity AC motor drive p. 2

If oL2 is still not resolved

  • Contact dealer or distributor for product issues or information discrepancies. p. 1
    “如有任何登錄資料與您訂貨資料不符或產品有任何問題,請您與接洽之代理商或經銷商連絡”