Delta VFD-L Series Error ocR: Overcurrent during acceleration

Delta VFD-L Series · taken from the manufacturer’s manual, pages cited

Error codeocR

This code indicates overcurrent during acceleration. The manual lists no action for this code.

Model
Delta VFD-L Series
Display shows
Overcurrent during acceleration (ocR)
Type
Error code
Source
Manual p. 2

What ocR means

Overcurrent during acceleration p. 2

Common causes

  • Check whether the input power voltage is normal p. 2
  • Check for sudden heavy load p. 2
  • Whether a three‑phase motor is being powered from a single phase or has a missing phase p. 2
  • Check if the motor is overloaded p. 2
  • Check whether the rated motor current (7-00) is appropriate p. 2
  • Check the electronic thermal‑release function settings p. 2
  • Increase motor capacity p. 2
  • Check whether the LVT1~V/T2-W/T3 output wiring is poorly insulated p. 2
  • Increase acceleration time p. 2
  • Decrease the torque boost setting (7-02) p. 2
  • Replace with a higher-output-capacity AC motor drive p. 2

If ocR is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ocR; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.