Error codeov
This code indicates the AC motor drive detected an overvoltage on the internal DC high-voltage side. The manual lists no action for this code.
- Model
- Delta VFD-L Series
- Display shows
- ov
- Type
- Error code
- Source
- Manual p. 2
What ov means
AC motor drive detected an overvoltage on the internal DC high‑voltage side p. 2
Common causes
- Check that the input voltage is within the AC motor drive’s rated input range and monitor for voltage spikes p. 2
- If the overvoltage is caused by motor back‑EMF raising the internal DC high‑voltage side, lengthen the deceleration time p. 2
If ov is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ov; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.