Error codeocA
This code indicates overcurrent during acceleration. The manual's first action is: “Check whether the wiring from U-V-W to the motor has poor insulation”
- Model
- Delta VFD-E
- Display shows
- Overcurrent during acceleration (ocA)
- Type
- Error code
- Source
- Manual p. 203
What ocA means
Overcurrent during acceleration p. 203
Common causes
- Check whether the screws between the AC motor drive and the motor are loose p. 203
- Increase acceleration time p. 203
- Replace with a higher output capacity AC motor drive p. 203
What to do
- Check whether the wiring from U-V-W to the motor has poor insulation p. 203
- Reduce the torque boost setting (07.02) p. 203
Before you service the product, read the safety instructions in the manual p. 150.
If ocA is still not resolved