Ground fault protection activated means the AC motor drive detects that the output is grounded and the ground current exceeds 50% of the drive’s rated current. The manual's first action is: “Check for short circuits or grounding in the wiring to the motor, verify whether the IGBT power module is damaged, and inspect the output side wiring for insulation failure”
- Model
- Delta VFD-E
- Display shows
- GFF
- Type
- Fault code
- Source
- Manual p. 204
What GFF means
Ground fault protection activated. When the AC motor drive detects that the output is grounded and the ground current exceeds 50% of the drive’s rated current. Note: This protection is for the AC motor drive, not for personnel. p. 204
Common causes
- Ground fault protection activated. When the AC motor drive detects that the output is grounded and the ground current exceeds 50% of the drive’s rated current. Note: This protection is for the AC motor drive, not for personnel. p. 204
What to do
- Check for short circuits or grounding in the wiring to the motor, verify whether the IGBT power module is damaged, and inspect the output side wiring for insulation failure p. 204
- 2240H 1 p. 204
Before you service the product, read the safety instructions in the manual p. 150.
If GFF is still not resolved
This page summarises what the manufacturer’s manual says about GFF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.