Delta C2000 Error oSL: Over slip error

Delta C2000 · taken from the manufacturer’s manual, pages cited

Error codeoSL

Over slip error means the motor slip exceeded the set limits for duration. The manual's first action is: “Check that motor parameters are correct; if the load is excessive, reduce the load. Verify the settings of parameters 05-26 and 05-27.”

Model
Delta C2000
Display shows
Over slip error (oSL)
Type
Error code
Source
Manual p. 375

What oSL means

Over slip error p. 375

Common causes

  • When slip exceeds the setting in parameter 05-26 and the duration exceeds the setting in parameter 05-27, an oSL occurs. p. 375

What to do

  1. Check that motor parameters are correct; if the load is excessive, reduce the load. Verify the settings of parameters 05-26 and 05-27. p. 375

Before you service the product, read the safety instructions in the manual p. 365.

If oSL is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about oSL; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.