Dell R710 Error B122C: CPU Power Fault. Power cycle AC.

Dell R710 server · taken from the manufacturer’s manual, pages cited

Fault codeB122C

A power fault was detected when the processor power was applied, which may require a power cycle to resolve. The manual's first action is: “Disconnect the system's AC power for 10 seconds, then restart the system. If the problem persists, see “Getting Help”.”

Model
Dell R710
Display shows
CPU Power Fault. Power cycle AC. (B122C)
Type
Fault code
Source
Manual p. 25

What B122C means

CPU Power Fault. Power cycle AC. p. 25

Common causes

  • A power fault was detected when the processor power was applied. p. 25

What to do

  1. Disconnect the system's AC power for 10 seconds, then restart the system. If the problem persists, see “Getting Help”. p. 25

Before you service the product, read the safety instructions in the manual p. 2.

If B122C is still not resolved

  • 请参阅“系统内存故障排除” p. 60
    “如果问题仍然存在,请参阅“系统内存故障排除””
  • 请参阅“USB设备故障排除” p. 60
    “请参阅“USB设备故障排除””

This page summarises what the manufacturer’s manual says about B122C; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Dell. Found a mistake? Report an error.