Dell R710 Error Codes

60 codes from pages 23–38 of the manual

This is the list of fault, error, warning codes the Dell manual gives for the R710 Dell R710 server. Find your code below and open it for what the manual says about its causes and what to do.

Fault codes from p. 23

Error codes from p. 23

CodeDisplay messageWhat it meansPage
B1114 Ambient Temp exceeds allowed range. p. 23
B1116 Memory disabled, temp above range. Power cycle AC. p. 23
E1210 Motherboard battery failure. p. 24
E1211 RAID Controller battery failure. p. 24
E1216 3.3V Regulator failure. p. 24
E1229 CPU # VCORE Regulator failure. p. 24
E122A CPU # VTT Regulator failure. p. 24
B122D Memory Regulator # Failed. p. 25
B122E On-board regulator failed. Call support. p. 25
B1310 Fan ## RPM exceeding range. Check fan. p. 25
B1311 Fan module ## RPM exceeding range. Check fan. p. 25
E1313 Fan redundancy lost. Check fans. p. 26
E1410 System Fatal Error detected. p. 26
E1414 CPU # temp exceeding range. Check CPU heatsink. p. 26
E1418 CPU # not detected. Check CPU is seated properly. p. 26
E141C Unsupported CPU configuration. Check CPU or BIOS revision. p. 26
E141F CPU # protocol error. Power cycle AC. p. 27
E1420 CPU Bus parity error. Power cycle AC. p. 27
E1422 CPU # machine check error. Power cycle AC. p. 27
E1610 Power Supply # (### W) missing. p. 27
E1614 Power Supply # (### W) error. p. 28
E161C Power Supply # (### W) lost AC power. p. 28
E1620 Power Supply # (### W) AC power error. p. 28
E1624 Lost power supply redundancy. Check PSU cables. p. 29
E1626 Power Supply Mismatch. p. 29
E1629 Power required > PSU wattage. Check PSU and config. p. 29
E1710 I/O channel check error. Review & clear SEL. p. 29
E1A12 One or both PCIe riser boards are missing. This prevents the system from booting. 丢失一个或两个 PCIe 提升板。这会阻止系统启动。 p. 33
E1A14 SAS cable A is missing or damaged. SAS 电缆 A 丢失或损坏。 p. 33
E1A15 SAS cable B is missing or damaged. SAS 电缆 B 丢失或损坏。 p. 33
E1A1D The USB cable connected to the control panel is missing or damaged. 连接到控制面板的 USB 电缆丢失或损坏。 p. 33
E2010 No memory detected in the system. 系统中未检测到内存。 p. 33
E2011 Memory detected but not configurable. An error was detected during memory configuration. 检测到内存,但是内存不可配置。配置内存期间检测到错误。 p. 33
E2012 Memory configured but unusable. p. 34
E2013 BIOS unable to shadow memory. p. 34
E2014 CMOS RAM failure. p. 34
E2015 DMA Controller failure. p. 34
E2016 Interrupt Controller failure. p. 34
E2017 Timer refresh failure. p. 35
E2018 Programmable Timer error. p. 35
E2019 Parity error. p. 35
E201A SuperIO failure. p. 35
E201B Keyboard Controller error. p. 35
E201C SMI initialization failure. Power cycle AC. p. 36
E201D Shutdown test failure. Power cycle AC. p. 36
E201E POST memory test failure. Check DIMMs. p. 36
E2020 CPU configuration failure. Check screen message. p. 36
E2021 Incorrect memory configuration. Review User Guide. p. 36
E2022 General failure during POST. p. 37
E2023 BIOS unable to mirror memory. p. 37
E2110 Multibit Error on DIMM ##. Reset DIMM. Multibit Error on DIMM ##. Reset DIMM. (DIMM ## 上多位错误。请重置 DIMM.) p. 37
E2111 SBE log disabled on DIMM ##. Reset DIMM. SBE log disabled on DIMM ##. Reset DIMM. (已禁用 DIMM ## 上的 SBE 日志。请重置 DIMM.) p. 37
E2113 Mem mirror OFF on DIMM ## & ##. Power cycle AC. Mem mirror OFF on DIMM ## & ##. Power cycle AC. (DIMM ## 和 ## 上的内存镜像关闭。请关闭交流电源再打开。) p. 38
I1910 Intrusion detected. Check chassis cover. Intrusion detected. Check chassis cover. (已检测到侵入。请检查机箱护盖。) p. 38
I1911 LCD Log Full. Check SEL to review all Errors. LCD Log Full. Check SEL to review all Errors. (LCD 日志已满。请检查 SEL,查看所有错误。) p. 38
I1912 SEL full. Review & clear log. SEL full. Review & clear log. (SEL 已满。请检查并清除日志。) p. 38

Warning codes from p. 28

Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Dell. Found a mistake? Report an error.