Canon iR2420/iR2320/iR2318 Error E003: Abnormal low temperature (detected by primary thermistor)

Canon iR2420/iR2320/iR2318 · taken from the manufacturer’s manual, pages cited

Error codeE003

An abnormal low temperature is detected by either the primary or secondary thermistor after reaching the target temperature during initial rotation. The manual's first action is: “- Check the fuser unit connector.”

Model
Canon iR2420/iR2320/iR2318
Display shows
Abnormal low temperature (detected by primary thermistor) (E003)
Type
Error code
Source
Manual p. 266

What E003 means

Abnormal low temperature (detected by primary thermistor) p. 266

Common causes

  • After the temperature detected by the primary thermistor reached the target, it did not reach the target temperature during the initial rotation. p. 266
  • After the temperature detected by the secondary thermistor reached the target, it did not reach the target temperature during the initial rotation. p. 266

What to do

  1. - Check the fuser unit connector. p. 266
  2. - Replace the fuser unit. p. 266
  3. - Replace the DC control board. p. 266

Before you service the product, read the safety instructions in the manual p. 4.

If E003 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Canon service.

This page summarises what the manufacturer’s manual says about E003; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Canon. Found a mistake? Report an error.