An abnormal high temperature is detected by either the primary thermistor at 240 °C or the secondary thermistor at 295 °C during temperature control. The manual's first action is: “- Check the fuser unit connector.”
- Model
- Canon iR2420/iR2320/iR2318
- Display shows
- Abnormal high temperature (detected by primary thermistor) (E001)
- Type
- Error code
- Source
- Manual p. 266
What E001 means
Abnormal high temperature (detected by primary thermistor) p. 266
Common causes
- During temperature control, the primary thermistor detected an abnormal high temperature (240 °C). p. 266
- During temperature control, the secondary thermistor detected an abnormal high temperature (295 °C). p. 266
What to do
- - Check the fuser unit connector. p. 266
- - Replace the fuser unit. p. 266
- - Replace the DC control board. p. 266
Before you service the product, read the safety instructions in the manual p. 4.
If E001 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Canon service.
This page summarises what the manufacturer’s manual says about E001; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Canon. Found a mistake? Report an error.