ABB ACS550-01 / ACS550-U1 Error 3010: STALL FUNCTION

ACS550-01/U1 drive · taken from the manufacturer’s manual, pages cited

Fault code3010

The Stall function is enabled to detect prolonged stall conditions and trigger a fault response based on the time set by parameter 3012. The manual's first action is: “This protection is active if the drive operates in the stall region (see the figure) for the time defined by 3012 STALL TIME. The "User Limit" is defined in Group 20: LIMITS by 2017 MAX TORQUE 1, 2018 MAX TORQUE 2, or the limit on the COMM input.”

Model
ABB ACS550-01 / ACS550-U1
Display shows
STALL FUNCTION (3010)
Type
Fault code
Source
Manual p. 150

What 3010 means

STALL FUNCTION p. 150

Common causes

  • This parameter defines the operation of the Stall function. p. 150
  • 0 = NOT SEL – Stall protection is not used. p. 150
  • 1 = FAULT – When the drive operates in the stall region for the time set by 3012 STALL TIME: p. 150
  • 2 = ALARM – When the drive operates in the stall region for the time set by 3012 STALL TIME: p. 150

What to do

  1. This protection is active if the drive operates in the stall region (see the figure) for the time defined by 3012 STALL TIME. The "User Limit" is defined in Group 20: LIMITS by 2017 MAX TORQUE 1, 2018 MAX TORQUE 2, or the limit on the COMM input. p. 150
  2. - The drive coasts to stop. - A fault indication is displayed. p. 150
  3. - An alarm indication is displayed. - The alarm disappears when the drive is out of the stall region for half the time set by parameter 3012 STALL TIME. p. 150

Before you service the product, read the safety instructions in the manual p. 6.

If 3010 is still not resolved

  • contact your local ABB representative for replacement p. 6
    “Never attempt to repair a malfunctioning drive; contact your local ABB representative for replacement.”
  • For more technical information, contact your local ABB representative. p. 7
    “For more technical information, contact your local ABB representative.”