ABB ACS550-01 / ACS550-U1 Error 3003: EXTERNAL FAULT 1

ACS550-01/U1 drive · taken from the manufacturer’s manual, pages cited

Fault code3003

EXTERNAL FAULT 1 defines how the drive reacts to an external fault signal, with options for disabling or using digital input D11 as the trigger source. The manual's first action is: “0 = NOT SEL – External fault signal is not used. 1 = DI1 – Defines digital input D11 as the external fault input. • Activating the digital input indicates a fault. The drive displays a fault (14, EXT FAULT 1) and the drive coasts to stop. 2...6 = DI2...DI6 – Defines digital input D12...D16 as the external fault input. • See D11 above. -1 = DI1(INV) – Defines an inverted digital input D11 as the external fault input. • De-activating the digital input indicates a fault. The drive displays a fault (14, EXT FAULT 1) and the drive coasts to stop. -2...-6 = DI2(INV)...DI6(INV) – Defines an inverted digital input D12...D16 as the external fault input. • See D11(INV) above.”

Model
ABB ACS550-01 / ACS550-U1
Display shows
EXTERNAL FAULT 1 (3003)
Type
Fault code
Source
Manual p. 148

What 3003 means

EXTERNAL FAULT 1 p. 148

Common causes

  • Defines the External Fault 1 signal input and the drive response to an external fault. p. 148

What to do

  1. 0 = NOT SEL – External fault signal is not used. 1 = DI1 – Defines digital input D11 as the external fault input. • Activating the digital input indicates a fault. The drive displays a fault (14, EXT FAULT 1) and the drive coasts to stop. 2...6 = DI2...DI6 – Defines digital input D12...D16 as the external fault input. • See D11 above. -1 = DI1(INV) – Defines an inverted digital input D11 as the external fault input. • De-activating the digital input indicates a fault. The drive displays a fault (14, EXT FAULT 1) and the drive coasts to stop. -2...-6 = DI2(INV)...DI6(INV) – Defines an inverted digital input D12...D16 as the external fault input. • See D11(INV) above. p. 148

Before you service the product, read the safety instructions in the manual p. 6.

If 3003 is still not resolved

  • contact your local ABB representative for replacement p. 6
    “Never attempt to repair a malfunctioning drive; contact your local ABB representative for replacement.”
  • For more technical information, contact your local ABB representative. p. 7
    “For more technical information, contact your local ABB representative.”

This page summarises what the manufacturer’s manual says about 3003; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.