Fault code12
MOTOR STALL indicates motor or process stall, operating in stall region. The manual's first action is: “Check for and correct: • Excessive load. • Insufficient motor power. • Parameters 3010...3012.”
- Model
- ABB ACS550-01 / ACS550-U1
- Display shows
- MOTOR STALL (12)
- Type
- Fault code
- Source
- Manual p. 245
What 12 means
MOTOR STALL p. 262
Common causes
- Motor or process stall. Motor is operating in the stall region. p. 262
What to do
- Check for and correct: • Excessive load. • Insufficient motor power. • Parameters 3010...3012. p. 262
Before you service the product, read the safety instructions in the manual p. 6.
If 12 is still not resolved
- contact your local ABB representative for replacement p. 6 “Never attempt to repair a malfunctioning drive; contact your local ABB representative for replacement.”
- For more technical information, contact your local ABB representative. p. 7 “For more technical information, contact your local ABB representative.”
This page summarises what the manufacturer’s manual says about 12; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.