INU 4 means a short-circuit in parallel connected phase module block 4, caused by Par. 9.01 bit 15. The manual's first action is: “Check the fibre optic cables between the NPBU board channel CH1 and the board of phase module block 4.
Check the motor and the motor cable.
Check all power plates in the phase module block 4. If a faulty power plate is detected, replace the whole phase module.”
- Model
- ABB ACA 635
- Display shows
- Short-circuit in parallel connected phase module block 4 (INU 4)
- Type
- Fault code
- Source
- Manual p. 66
What INU 4 means
Short-circuit in parallel connected phase module block 4 p. 66
Common causes
- Par. 9.01 bit 15 p. 66
What to do
- Check the fibre optic cables between the NPBU board channel CH1 and the board of phase module block 4.
Check the motor and the motor cable.
Check all power plates in the phase module block 4. If a faulty power plate is detected, replace the whole phase module. p. 66
Before you service the product, read the safety instructions in the manual p. 6.
If INU 4 is still not resolved
- contact an ABB service representative p. 61 “If not, contact an ABB service representative.”
This page summarises what the manufacturer’s manual says about INU 4; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.