This application note describes a liquid separation method using Agilent Bond Elut Plexa PCX for mixed mode ion exchange to fractionate acidic, neutral, and basic drugs from plasma. The method uses mixed mode polymer ion exchange technology to retain neutral and acidic compounds from biofluids via hydrophobic interactions and concentrates basic compounds by interacting with the sorbent’s cation exchange properties.
This document presents a case study on the application of Agilent's 610 FTIR Fourier Transform Infrared (FTIR) microscopes for material analysis. It highlights the ability of the microscopes to characterize the spatial distribution of components and identify the chemical nature of a sample. The document also discusses the various measurement modes and the added capability of automated infrared mapping analysis with a motorized sample stage.
This document describes the features and characteristics of a NPN silicon RF power transistor called AVD075P. It has features such as a maximum operating current of 6.5A, maximum peak voltage of 55V, and maximum power dissipation of 250W.
This is a NPN silicon RF power transistor with a maximum current of 6.5 A, a maximum voltage of 55 V and a maximum power of 250 W. The product features the Omnigold™ metallization system.
This article discusses the use of the Cary Absolute Specular Reflectance accessory for measuring the optical constants of thin films. By measuring the transmittance and reflectance, the dispersion and extinction coefficient of the films can be obtained, and various useful quantities such as the dielectric function and absorption coefficient can be calculated.
This document describes the method and results of well-to-well repeatability testing for a 96-well microplate using the Agilent Cary Eclipse Microplate reader. By adopting correct laboratory procedures and utilizing the reader's alignment function, variations in well-to-well volume and meniscus shape can be minimized. The Agilent Cary Eclipse Microplate reader has a well-to-well repeatability of less than 2%, compared to the 5% repeatability of conventional instruments.
This article describes a method for determining the water content in tobacco using near infrared spectroscopy, and compares it with oven drying and Karl Fischer titration. The method allows for accurate and reproducible measurement of water content.
This application note describes the steps involved in measuring the cover and shade protection factors of synthetic shadecloth. The method is based on measuring the absorption of UVR by the shadecloth samples using a spectrophotometric method, from which the shade protection factor is determined.