Key facts
- Brand
- Vacon
- Model
- Vacon 20
- Category
- inverter
- Industry
- Industrial
- Documents
- 10
- Languages
- EN · RU · ZH · DE · ES
- Last added
- 2026-11-13
Start here

Vacon 20 AC Drive Quick Guide
This document serves as a quick guide for the installation and setup of the Vacon 20 AC drive. It outlines essential steps for mounting the unit, connecting power and motor cables, and performing a basic Quick Modbus setup. The guide emphasizes safety precautions, noting that only a competent electrician should perform electrical installations and highlighting specific risks regarding live components and earth leakage currents.
The document includes detailed mechanical installation instructions for various models (MI1-MI5), covering screw, DIN-rail, and flange mounting options with specific spacing requirements. It also provides cabling diagrams for power connections and lists technical specifications, including power ratings, nominal input currents, and mechanical dimensions for different voltage series (115V, 380-480V, and 600V).
Vacon 20 specifications
| Mains voltage (1~ series) | 115 V, 50 / 60 Hz |
|---|---|
| Mains voltage (3~ series) | 380 - 480 V, 50 / 60 Hz |
| Earth leakage current | Exceeds 3.5 mA AC |
| Power rating (MI1, 380-480V) | 0.37 kW (0.5 HP) |
| Power rating (MI5, 380-480V) | 18.5 kW (25 HP) |
| Power rating (MI3, 600V) | 5.5 kW (7.5 HP) |
Source: Vacon 20 AC Drive Quick Guide
All Vacon 20 documents by type
The shortest path to a working setup, usually only a few pages.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
Who is allowed to carry out the electrical installation?
Only a competent electrician is allowed to carry out the electrical installation.
What is the tightening torque for power cables?
The tightening torque for power cables is 0.5 - 0.6 Nm (4-5 in.lbs).
Where can the full Vacon 20 User Manual be downloaded?
From www.vacon.com under Support & Downloads.
What cooling clearances must be left around the Vacon 20 during mounting?
Leave 100 мм above, 50 мм below, and 20 мм on both sides of the drive.
What mains input voltages does the Vacon 20 support?
It supports 115 V, 208–240 V, 380–480 V and 600 V mains inputs, with -15% to +10% variation.
What is the output frequency range of the Vacon 20?
The output frequency range is 0…320 Hz.