Tuttnauer 1730 2340 2540 3140 3850 3870 E EK EA EKA Manual
This document is the Operation Manual for the Aeroflex IFR 6000 Test Set, designed for testing XPDR, DME, TCAS, ADS-B, TIS, and TIS-B systems. The manual includes safety warnings, export control notices, and instructions for qualified technical personnel regarding servicing and operation.
The manual specifies that all servicing must be performed by qualified technical personnel as the unit contains no operator serviceable parts. It also details safety precautions, including the use of double-shielded cables no longer than 3 meters, proper grounding, and the use of recommended fuses. Additionally, it warns about potential electromagnetic interference (EMI) and provides a Declaration of Conformity.
Tuttnauer 3870 E specifications
| Reservoir volume | 3 lit. 0.8 gal (Models 1730, 2340, 2540, 3140) |
|---|---|
| Reservoir volume | 7.3 lit. 1.93 gal (Models 3850, 3870) |
| Maximum Allowable Working Pressure | 2.76 bar (40 psi) |
| Load No. counter range | 0 to 250 |
Source: Tuttnauer Electronic Table-Top Autoclaves Operation & Maintenance Manual
All Tuttnauer 3870 E documents by type
Disassembly, diagnostics and part numbers, for repair.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
How can the air filter be replaced on models EA and EKA?
The air filter replacement procedure is described in section 10.2, titled “Replacing the Air Filter (Models EA, EKA).”
From: Tuttnauer 1730-3870 Electronic Tabletop Autoclave Operation & Maintenance Manual
What is the maximum solid load for model 2540?
Model 2540 can hold up to 8.8 lb (4.0 kg) of solid load.
From: Tuttnauer 1730-3870 Electronic Tabletop Autoclave Operation & Maintenance Manual
What is the warranty period for the autoclave?
The instrument is guaranteed to be free from defects in material and workmanship for one year.
From: Tuttnauer Electronic Table-Top Autoclaves Operation & Maintenance Manual
How often should safety valves be checked?
Safety valves must be ensured to be functioning once a month.
From: Tuttnauer Electronic Table-Top Autoclaves Operation & Maintenance Manual
What is the warranty period for Tuttnauer autoclaves?
Tuttnauer warrants all new autoclaves for a period of two full years against defects in materials and workmanship.
From: Tuttnauer Electronic Tabletop Autoclaves Operation & Maintenance Manual
What are the operating temperature conditions?
The autoclave is intended for normal environment conditions with a room temperature range of 41º F to 104º F (5º C to 40º C).
From: Tuttnauer Electronic Tabletop Autoclaves Operation & Maintenance Manual