SWAN SWAN 1000 PIR and Microwave Motion Detector Installation Guide

SWAN SWAN 1000 PIR and Microwave Motion Detector Installation Guide

Installation Guide 2 pages · 504 KB · RU

This document provides installation instructions for the SWAN SWAN 1000, a professional passive infrared and microwave motion detector. It covers site selection, mounting procedures for wall or corner installation, and wiring connections for power, tamper, and relay outputs. The guide also details how to configure the device's sensitivity for both infrared and microwave channels and set the animal immunity threshold. This manual is written in Russian.

Read online

SWAN 1000 specifications

Detection method四元红外 and 微波
Operating voltage8.2 – 16 V DC
Trigger current consumption25.5 mA
Standby current consumption16.5 mA
Alarm outputNC 28 VDC 0.1 A with 10 Ω resistor
Dimensions123 mm × 62 mm × 38 mm
Weight120 g
Preheat time1 minute
Alarm time2 ± 1 s

Source: SWAN 1000 Passive Infrared and Microwave Dual-Technology Detector Installation Manual

All SWAN 1000 documents by type

Installation Guide 2

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

What is the animal immunity weight limit for the SWAN 1000?

The detector ignores animals up to 25 kg, or 15 kg if the PET switch is set to ON.

From: SWAN SWAN 1000 PIR and Microwave Motion Detector Installation Guide

How do I set the pet‑immunity function?

Use the PET switch: set it to ON to protect pets up to 15 kg, or set it to OFF to protect pets up to 25 kg.

From: SWAN 1000 Passive Infrared and Microwave Dual-Technology Detector Installation Manual

How can I adjust the detection distance?

Turn the MW knob; the middle position gives a 15 m range, while the minimum position reduces the range to 7 m.