SEW-EURODRIVE DFP21B PROFIBUS DP-V1 Fieldbus Interface Manual
The document serves as a comprehensive guide for the DFP21B fieldbus interface, covering its features, assembly, and installation into MOVIDRIVE® MDX61B and MOVITRAC® B drives. It details the setup of PROFIBUS DP and DP-V1 connections, including baud rates, shielding, and station address configuration.
The manual further explains project planning using GSD files, parameter setting procedures via PROFIBUS, and the operation of MOVITOOLS® MotionStudio. It also includes sections on error diagnostics, technical data, and disposal regulations.
SEW DP-V1 specifications
| Product Name | Fieldbus Interface DFP21B |
|---|---|
| Protocol Support | PROFIBUS DP-V1 |
| Compatible Drive 1 | MOVIDRIVE MDX61B |
| Compatible Drive 2 | MOVITRAC B |
Source: SEW-EURODRIVE DFP21B PROFIBUS DP-V1 Fieldbus Interface Manual
All SEW DP-V1 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What inverters are compatible with the UFP11A?
The interface is used for connecting MOVITRAC® 07 inverters via the SBus.
From: SEW-EURODRIVE UFP11A PROFIBUS DP-V1 Interface User Manual
Where must the terminating resistor be installed?
The terminating resistor must be connected at the end of the system bus connection, while it should be disconnected at other devices.
From: SEW-EURODRIVE UFP11A PROFIBUS DP-V1 Interface User Manual
What is the document reference number for this manual?
The document reference number is 41479019.
From: SEW-EURODRIVE DFP21B PROFIBUS DP-V1 Fieldbus Interface Manual
Which software is used for operating the drive via PROFIBUS?
The drive can be operated via MOVITOOLS MotionStudio.