Key facts
- Brand
- RAE Systems
- Model
- ToxiRAE II PGM-1100 Series
- Category
- detectors
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2026-11-16
Start here

RAE Systems ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual
This is the user manual (045-4003-001, Rev A, December 2012) for the RAE Systems ToxiRAE II PGM-1100 Series personal toxic gas monitor. The ToxiRAE II is a single-gas monitor that continuously displays toxic gas concentrations together with STEL, TWA and Peak values, and it raises high, low, TWA and STEL alarms. The manual opens with standard contents and calibration kit lists, a general description, a physical description and an explanation of the display features.
It then explains how to turn the monitor on and off, how to read STEL, TWA and PEAK, and how to enter Program Mode and perform zero and span calibration or change preset limits and span gas values. A maintenance section covers changing the battery, the filter and the sensor, and the back of the manual gives specifications, Table A with sensor configurations and Table B with alarm signals for H2S, plus RAE Systems contact and service information.
RAE Systems ToxiRAE II PGM-1100 Series specifications
| Size | 3.6" (9.3 cm) x 1.9" (4.9 cm) x 0.9" (2.2 cm) |
|---|---|
| Weight | 3.6 oz (102 gm) with clip |
| Battery | User-replaceable 2/3 AA high-capacity Lithium battery |
| Operating Period | 2 years typical battery life for CO/H2S/O2 sensors or 730 minutes of alarm; typical 1 year or 360 minutes of alarm for other sensors |
| Display | Easy-to-read LCD for continuous display of concentration in ppm and text messages |
| Audible Alarm | 90dB at 12" (10 cm) |
| IP Rating | IP-65, protected against dust and low pressure jets of water from all directions |
| Temperature | -40° to 131° F (-40° to 55° C) for O2, CO, and H2S |
| Humidity | 0-95% relative humidity (non-condensing) |
| Calibration | Two-point field calibration; auto-zero at startup (firmware version 1.4 only) |
| Warranty | 2-year warranty for instrument and CO/H2S/O2 sensors; 1-year for all other sensors |
Source: RAE Systems ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual
All RAE Systems ToxiRAE II PGM-1100 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How does the ToxiRAE II monitor turn on and off?
Hold the button down and release when the display says "on" to start it; hold the button through the "5…4… 3… 2… 1… OFF" sequence to turn it off, and the display goes blank.
From: RAE Systems ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual
How long before the STEL reading appears?
The STEL is the average reading for the last 15 minutes and does not appear until 15 minutes have elapsed.
From: RAE Systems ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual
How do I turn the monitor on?
Hold the button down and release when the display says 'on.' The monitor will perform a self-test preceding warm-up.
From: ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual
What does the STEL reading represent?
The Short Term Exposure Limit (STEL) is the average reading of the gas concentration for the last 15 minutes.
From: ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual